ao-cal-freq - Calibrate AltOS flight computer frequency
ao-cal-freq [-T
tty-device] [--tty
tty-device] [-D
altos-device] [--device
altos-device] [-v] [--verbose] [-n]
[--nosave] [-o
cal-value-output-file] [--output
cal-value-output-file]
ao-cal-freq drives the frequency calibration process and saves the
result.
- -T tty-device | --tty tty-device
- This selects which tty device the debugger uses to
communicate with the target device. The special name 'BITBANG' directs
ao-dbg to use the cp2103 connection, otherwise this should be a usb serial
port connected to a suitable cc1111 debug node.
- -D AltOS-device | --device AltOS-device
- Search for a connected device. This requires an argument of
one of the following forms:
- TeleMega:2
TeleMega
2
- Leaving out the product name will cause the tool to select
a suitable product, leaving out the serial number will cause the tool to
match one of the available devices.
- -o cal-value-output-file | --output
cal-value-output-file
- Writes the resulting calibration value to the specified
file.
- -n | --nosave
- Inhibits saving the calibration value on the device.
Necessary for devices which don't have on-board configuration
storage.
- -v | --verbose
- Makes ao-cal-freq chatty about communication with
the target device.
ao-cal-freq opens the target device, interactively calibrates the
frequency, then shows the resulting calibration values and (optionally) saves
them to configuration memory and/or a file.